How can I minimize the moisture adsorption on FR4 PCB?

Although the adsorption of moisture by FR4 is quite low, what is the best way to minimize it or eliminate it completely?

Adsorption is a chemical process that occurs on the surface and can affect surface resistivity. Since you are talking about PCB mass, it sounds like you are actually talking about moisture absorption which is diffusion into the bulk of the material.

  • If there are any fixing holes, it will be impossible to eliminate them completely.
  • I have some products where the use of this sealant is mandated (they are in ship-board aircraft). I only mention this to show there are solutions, if there is a requirement for complete sealing.
  • Simply covering most of the PCB with solder mask will reduce the absorption of moisture.
  • From a system point of view, other than the bare PCB, it would be important to avoid components that absorb moisture- which would include plastic-packaged parts, but especially polyamide (Nylon) fasteners etc. which can absorb an enormous amount of moisture (as much as 10%)- enough to cause large dimensional changes as well as mass changes.

Read More: A Comprehensive Guide to FR4 Thermal Conductivity

#PCB Manufacturing

Picture of Oliver Smith

Oliver Smith

Oliver is an experienced electronics engineer skilled in PCB design, analog circuits, embedded systems, and prototyping. His deep knowledge spans schematic capture, firmware coding, simulation, layout, testing, and troubleshooting. Oliver excels at taking projects from concept to mass production using his electrical design talents and mechanical aptitude.
Picture of Oliver Smith

Oliver Smith

Oliver is an experienced electronics engineer skilled in PCB design, analog circuits, embedded systems, and prototyping. His deep knowledge spans schematic capture, firmware coding, simulation, layout, testing, and troubleshooting. Oliver excels at taking projects from concept to mass production using his electrical design talents and mechanical aptitude.

What Others Are Asking

How can I mount a pulse oximeter on the surface of PCB without putting too much stress?

The PCB has a pulse oximeter mounted on the surface, and it’s tolerance is 0.6mm. The problem is the pulse oximeter needs to touch the bottom case at all times. How to best mount the PCB in the case without putting too much stress on the pulse oximeter? Will screws with flexible washers be all right? Sadly separating pulse oximeter from main PCB is not an option.

Can I design SMD elements on the back of THT?

I’m designing a PCB right now and found out I can save a lot of space using the back of THT elements. Is it legit to design like that? Are there any problems that might occur? 

Read Detailed Advice From Blog Articles

Scroll to Top